Magnetek Enrange CAN-6 Manuale delle Istruzioni Pagina 18

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 17
Flex 8EX System Instruction Manual
December 2013
Page 18 of 44
52134 867
FUNCTION
LED 1LED 2LED 3LED 4
4.1.2 Push Button Functions with LED Displays
4.1.2.1 Standard Push Button Configuration (Transmitter Toggle)
Set the transmitter toggle (latching output relay) function by adjusting the 8-position
function dip-switch located on the backside of the transmitter encoder board (refer to Fig.
09 below). The LED 1 through LED 4 shown inside the shaded box (see below) illustrates
which LED on the transmitter will light up when the designated push button (PB5 - PB8)
is pressed.
(Fig. 09)
DIP PB5 PB6 PB7 PB8
1
00000000 Normal Normal Normal Normal
2
00000101 Normal Normal Normal LED 4
3
00000110 Normal Normal LED 3 LED 4
4
00000111 Normal LED 2 LED 3 LED 4
5
00001000 LED 1 LED 2 LED 3 LED 4
* PB5…PB8 Push button number
* Normal Normal momentary contact
* LED 1…LED 4 Transmitter toggled with designated LED Display